ALK 3000K
BASIC
ALK 3000K
- Material AlMg Si 0.5
- Double-walled construction
- Walls, doors and roof ventilated
- 12 mm distance between the inner and outer walls all around
- Doors and rear walls can be removed
- Split Bottom Plate
- Flexible use
- Housing closed on all sides
- In the interior, a circumferential frame profile with milling for further universal installations
- Protection class IP 55
- Impact resistance IK 10 according to EN 62262

STANDARD VERSION
ALK 3000K
- Cabin made of seawater-resistant aluminium construction profiles
- Dust and blast water resistant IP 55 according to DIN EN 60529
- Impact resistance IK 10 according to EN 62262
- Double-walled roof
- Doors with bar lock and swivel lever handle, prepared for profile cylinders
- Side walls permanently mounted
- Door/s and rear panel removable
- Door stop “gas pressure”
- Cabin below with split floor panel
- 12 mm distance between inner and outer wall
- Inner back panel and side walls without air vents
- In double-walled roof with at least 2 radial fans*
- Door(s) and side walls inside with air inlet filter(s)*
- High-quality, weatherproof 2-component wet painting on the outside
- structured, RAL 7032 or 7035
* The number of fans and inlet filters depends on the air conditioning calculation and case size
AIR CONDITIONING
Rear ventilation with filter fan system
In “warmer” applications (high power dissipation), the natural convection caused by the double-walled design is supported by integrated inlet and outlet filters in the inner side or door wall as well as by sufficiently dimensioned radial fans in the inner roof panel.
- The use of an air conditioning package does not change the external appearance (no entry or exit filters visible on the outside of the housing).
- The IP 55 protection class ensures the highest level of vandalism protection.
- In 95% of the usual applications, e.g. in the water/wastewater sector, with the simultaneous use of PLCs with higher power dissipation, this is completely sufficient.
- Significantly lower investment and maintenance costs compared to air conditioners.
On request, we can support you in calculating a sufficiently dimensioned air conditioning package, taking into account the location, the individual environmental conditions and the simultaneous power loss. Of course, this service is free of charge for you.

NATURAL CONVECTION
with fan support
With the help of fans (1) installed between the inner roof and the outer roof, the heated air is released via the roof.
Inlet filters on the inside of the doors (2) and side walls (3) ensure that cold air filtered through the double wall is sucked in from close to the floor for cooling.